MONITORING AND OPERATIONS

24/7 remote monitoring & operations

Real, in-house BESS operators in our NERC CIP Medium control room in Austin, Texas — monitoring BESS and Solar PV to maximize uptime and protect your warranties.

In-house, not subcontracted

Some EMS providers subcontract monitoring to an unknown party. Others only monitor the software. Fractal EMS provides experienced, in-house asset monitoring — handling technical support, troubleshooting, incident response, and coordination from our Austin control room.
Fractal EMS in-house control room in Austin, Texas
17+ GWh
In operations
37 GWh
Awarded projects
24/7
Human monitoring
NERC CIP
Medium control room

Included remote monitoring service package

Monitoring & management

  • 24/7 real-time human monitoring & proactive asset management
  • BESS control system hardware health & status
  • Remote troubleshooting, restoration & inverter resets
  • Oversee SoC, C-rate & DoD
  • Fire-suppression panel alarms reported
  • Escalate & notify the owner of significant events
  • Alert within 5 minutes of any availability-reducing event

Vendor liaison

  • Primary advocate for warranty claims with equipment vendors
  • Direct liaison between owner & equipment providers, estimating site impact
  • Diagnose complex issues with manufacturers (cooling-loop pressure, sensor lockups, nuisance alarms)
  • Coordinate corrective & preventative maintenance

Enhanced analytics & reporting

  • Monthly techno-economic assessments of profitability, asset health & financials
  • Monthly performance optimization of settings & parameters
  • Continuous anomaly detection & trend analysis
  • Outage root-cause analysis with long-term mitigation

Troubleshooting & engineering support

  • High-tier diagnostics for complex control anomalies, communication faults & balance-of-plant (BOP) failures
  • Monthly engineering, consulting or software-development support to keep the system reliable and optimized

Event notification tiers

Tier 0
Planned securing of an inverter or power unit; scheduled maintenance (charges, benchmark testing, upgrades).
Tier 1
Unplanned loss of an inverter or rack with no impact to site operations or market obligations (whether or not it resets).
Tier 2
Unplanned loss impacting site operations or market obligations; any Tier 1 event during working hours.
Tier 3
Serious injury (ambulance/fire), site casualty (fire/flood), or impending severe weather / earthquake.
Want 24/7 eyes on your assets?