CYBER RISK ASSESSMENT

Cyber risk assessment for battery storage

Fractal's in-house penetration testing team assesses new and existing BESS and hybrid plants, remotely or on site. You get our findings and the corrective actions needed to close each gap and harden the site.

Why now

Batteries are now targets

In under a year, attackers took renewable and storage sites offline in two countries, and new modeling puts a coordinated attack on battery fleets close to certain within five years.

30+Wind and solar farms hit in one day
0%Availability two months after an attack
92%Modeled odds of a major fleet attack by 2031
30MPeople affected in a modeled ERCOT attack
Illustration of a cyberattack on the power grid
December 2025 · Poland

Coordinated attack on 30+ sites

Attackers corrupted RTU firmware, wiped controllers and deleted system files. The farms lost communication with the grid operator. They got in through internet-facing firewalls and VPNs, many without MFA.

Battery energy storage site
August 2026 · Chile

Solar and BESS taken offline

A 103 MW solar plant with a 98 MW / 312 MWh battery asked for a forced disconnection after a cyberattack during commissioning. Two months later both were still at 0% availability.

Modeled odds of a major attack by 2031Current practice92%Moderate improvements78%IEC 62443 + attack drills61%
September 2026 · GRIDLOCK study

Fleets can move the grid

10,000 simulations of a coordinated attack on cloud-controlled battery fleets. Compromising about 1,500 units in ERCOT could disrupt power for up to 30 million people.

What we find on client sites

When Fractal takes on existing assets or supports a new procurement, we find the same problems again and again. The attackers in Poland used several of them.

01

Vendor and maintenance accounts that are shared or over-privileged, with no oversight of technician access

02

One admin login used by everyone, so there is no record of who changed what

03

Internet-facing firewalls and VPNs with local accounts, no MFA and unpatched firmware

04

Firewalls with no self-protection rules, no geographic blocking and broad access rules

05

Field devices on default passwords, without TLS, with SSH exposed and open MQTT or REST endpoints

06

Security cameras and other peripherals sharing the control network

07

Office computers that connect to plant controls, with no phishing training or audit logging

08

The cheapest security licenses, which limit what can be detected or blocked

09

Patches put off because they affect schedule and support

10

Monitoring and patching that stop when an asset is sold

How the assessment works

Find every way in, then close it

We map every path into the plant, test each one the way an attacker would, and hand you the corrective action for every gap we find.

STEP 1 · MAP THE ATTACK SURFACEEvery path into the plant: internet-facing firewalls and VPNs, vendor access and hidden modems. STEP 2 · FIND THE GAPSOur penetration testers probe each path and device, the way an attacker would. STEP 3 · CLOSE THEMEach finding comes with the corrective action that closes the gap and hardens the site. STEP 4 · HARDEN AND MONITORNamed accounts, segmented networks and monitored remote sessions keep the site closed. PLANT CONTROL NETWORK CAMERA VLAN INTERNET VENDORremote access FIREWALLVPN SWITCH EMS / PPCcharge and discharge BMSbattery firmware INVERTERS / PCS RTAC + FIELDdevices CAMERAS OFFICE PC OEMcloud 1VPN without MFA MFA + named accounts 2Shared admin login Unique logins, audit trail 3Default passwords, open ports TLS, closed ports 4Cameras on control network Segmented VLAN 5Hidden cellular modem Modem disabled 6Phishing-prone office PC Training and logging 1 · MAP 2 · FIND THE GAPS 3 · CLOSE THEM 4 · HARDEN AND MONITOR

Two ways to assess your site

For new and existing assets, including plants that came with someone else's network.

Option 1

Remote assessment

A less intrusive review with no site visit.

Site network and segmentation
Remote access paths, VPNs and vendor accounts
Internet-exposed devices and services
Best for a fast baseline across one site or a portfolio
Option 2

On-site assessment

A full penetration test and cybersecurity assessment. The most thorough option.

Plant control systems: EMS, PPC, BMS and SCADA
Network equipment, firewalls and switches
Field devices, modems and peripherals
Best before COD, after an acquisition, or after an incident

What you receive

Either way, you receive an outline of our findings and the corrective actions needed to close each gap and harden the site.

Current policy and its gaps

Rules focus on who made the equipment

Federal policymakers acted this year and Texas has tightened its rules since 2021, but both focus on who owns the equipment and where it was made, not on how the site is secured.

Executive Order 14421

Declared a national emergency over the bulk power system supply chain. Covers inverters, storage and control systems, and their software, firmware and remote access, when tied to covered countries. DOE rules are due December 24 and can reach equipment already in service.

FCC Covered List

Foreign-made inverters and BESS equipment with remote or wired communications are blocked from new equipment authorizations. Models already certified can still be sold and installed.

Texas Lone Star Infrastructure Protection Act

Bars grid contracts that give designated foreign companies remote access or control. Compliance is by attestation, and access for warranty and support is allowed.

What none of them cover

No rule yet sets a baseline for how a site is networked: protocols, encryption, credentials or who watches remote sessions. Equipment that passes every origin test can still sit on a flat network with default passwords.

Risks inside the equipment

Some of the biggest exposures ship with the equipment itself.

Undisclosed communication devices

Equipment from foreign and U.S. suppliers alike ships with data acquisition systems and cellular modems that let the manufacturer push remote updates. Most buyers don't know they are there, no one monitors them, and they connect around the owner's firewall.

Supplier-controlled EMS and PPC

The EMS and PPC issue the charge and discharge commands. A coordinated fleet attack depends on those commands, so a supplier that controls them can control the plant.

Battery management systems

Backdoors can be added to BMS firmware during manufacturing, shipping or service, and time signals can be spoofed to line up commands across a fleet. Traffic is often unencrypted, and many systems cannot check whether their firmware has been altered.

Coordinated fleet attacks

An attacker who controls enough batteries can take them offline together, or charge and discharge them in sync to push frequency outside limits, tripping relays and risking blackouts.

Contract requirements

Write security into the purchase

Our consultants review commercial and technical exhibits and help buyers secure terms like these.

No undisclosed cellular modems, data acquisition systems or radio hardware; every communication path disclosed

No vendor remote access except through an owner-controlled gateway with named accounts, MFA and session logging

No firmware or software update without owner approval and signature checks

Encrypted protocols, unique credentials and segmented networks from the start

Managed switches, firewalls and other network equipment from domestic sources

Monitoring and patching obligations that transfer with the asset when it is sold

Owner or independent control of the EMS and PPC

Suppliers that follow NIST CSF 2.0, ISO/IEC 27001 and IEC 62443, including 62443-2-4 and 62443-4-1

ISO 9001 quality management for manufacturing, configuration and change control

No terms that give a specified foreign entity effective control of the facility, which can put the Section 48E credit at risk

Why Fractal EMS

In-house penetration testing

Our own team assesses new and existing assets, remotely or on site.

Cybersecurity built in

Fractal EMS builds security into its controls, with its own cyber and IT teams.

Domestic controls and BMS

Our controls, including our three-level BMS, are domestic and free of foreign entities of concern.

Standards-based

Engineered to NIST 800-53 and IEC 62443, with ISO 27001 and a NERC CIP Medium operations center.

24/7 operations center

Our Austin ROC monitors sites around the clock. In-house, never off-shored.

Contract review

Subject-matter experts in commercial and technical exhibits for equipment purchases.

Buying equipment for 2027, or own a site that came with someone else's network? Schedule an assessment.
Request an assessment
Fractal EMSCYBER RISK ASSESSMENT